{"id":4021,"date":"2022-01-21T04:08:58","date_gmt":"2022-01-21T04:08:58","guid":{"rendered":"https:\/\/www.ee.iitb.ac.in\/web?post_type=course_lists&#038;p=4021"},"modified":"2022-01-21T04:08:59","modified_gmt":"2022-01-21T04:08:59","slug":"ee-785-electromagnetic-interference-and-compatibility","status":"publish","type":"course_lists","link":"https:\/\/www.ee.iitb.ac.in\/web\/course_lists\/ee-785-electromagnetic-interference-and-compatibility\/","title":{"rendered":"EE 785 &#8211; Electromagnetic Interference and Compatibility"},"content":{"rendered":"\n<p>BASIC THEORY: Intra and inter-system EMI, Elements of Interference:<br>Conducted and Radiated EMI emission and susceptibility, EMC Engineering Application.<br><br><br>COUPLING MECHANISM: Coupling paths, Coupling via the supply network, Common mode coupling, Differential mode coupling, Impedance coupling, Radiative coupling, Ground loop coupling, Cable related emissions and coupling, Transient sources, Automotive transients. Categorization of the electromagnetic interference: emission, susceptibility, transients, crosstalk, shielding and compatibility, signal integrity.<br><br>EMI MITIGATION TECHNIQUES: Working principle of Shielding, LF Magnetic shielding, Apertures and shielding effectiveness, Choice of Materials for H, E, and free space fields, Gasketting and sealing PCB Level shielding,<br>Principle of Grounding.<br><br>STANDARDS AND REGULATION: Need for Standards, EMI Standardizing for different applications. IEC, ANSI, FCC, AS\/NZS, CISPR, BSI, CENELEC, ACEC. MIL461E<br><br>EMI TEST METHODS AND INSTRUMENTATION: Fundamental considerations, EMI Shielding effectiveness tests, Open field test, TEM cell for immunity test, Shielded chamber, Shielded anechoic chamber, EMI test receivers, Spectrum analyzer, EMI test wave simulators, EMI coupling networks, Line impedance stabilization networks, Feedthrough capacitors, Antennas, Current probes.<br><br>BASICS OF BIOLOGICAL EFFECTS OF EM WAVES: Ionizing and non-ionizing radiation. Theoretic and diagnostic use of EM waves. Measurement techniques of EM radiation. Protective design techniques.<\/p>\n","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>EE 785 - Electromagnetic Interference and Compatibility &ndash; EE IIT Bombay<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EE 785 - Electromagnetic Interference and Compatibility &ndash; EE IIT Bombay\" \/>\n<meta property=\"og:description\" content=\"BASIC THEORY: Intra and inter-system EMI, Elements of Interference:Conducted and Radiated EMI emission and susceptibility, EMC Engineering Application. COUPLING MECHANISM: Coupling paths, Coupling via the supply network, Common mode coupling, Differential mode coupling, Impedance coupling, Radiative coupling, Ground loop coupling, Cable related emissions and coupling, Transient sources, Automotive transients. Categorization of the electromagnetic interference: emission, &hellip; EE 785 &#8211; Electromagnetic Interference and Compatibility Read More &raquo;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/\" \/>\n<meta property=\"og:site_name\" content=\"EE IIT Bombay\" \/>\n<meta property=\"article:modified_time\" content=\"2022-01-21T04:08:59+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/\",\"url\":\"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/\",\"name\":\"EE 785 - Electromagnetic Interference and Compatibility &ndash; EE IIT Bombay\",\"isPartOf\":{\"@id\":\"https:\/\/www.ee.iitb.ac.in\/web\/#website\"},\"datePublished\":\"2022-01-21T04:08:58+00:00\",\"dateModified\":\"2022-01-21T04:08:59+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.ee.iitb.ac.in\/web\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"EE 785 &#8211; Electromagnetic Interference and Compatibility\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.ee.iitb.ac.in\/web\/#website\",\"url\":\"https:\/\/www.ee.iitb.ac.in\/web\/\",\"name\":\"EE IIT Bombay\",\"description\":\"Department of Electrical Engineering, IIT Bombay\",\"publisher\":{\"@id\":\"https:\/\/www.ee.iitb.ac.in\/web\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.ee.iitb.ac.in\/web\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.ee.iitb.ac.in\/web\/#organization\",\"name\":\"Department of ELectrical Engineering | IIT Bombay\",\"url\":\"https:\/\/www.ee.iitb.ac.in\/web\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.ee.iitb.ac.in\/web\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.ee.iitb.ac.in\/webwp-content\/uploads\/2021\/11\/MicrosoftTeams-image-2.png\",\"contentUrl\":\"https:\/\/www.ee.iitb.ac.in\/webwp-content\/uploads\/2021\/11\/MicrosoftTeams-image-2.png\",\"width\":93,\"height\":41,\"caption\":\"Department of ELectrical Engineering | IIT Bombay\"},\"image\":{\"@id\":\"https:\/\/www.ee.iitb.ac.in\/web\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"EE 785 - Electromagnetic Interference and Compatibility &ndash; EE IIT Bombay","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/","og_locale":"en_US","og_type":"article","og_title":"EE 785 - Electromagnetic Interference and Compatibility &ndash; EE IIT Bombay","og_description":"BASIC THEORY: Intra and inter-system EMI, Elements of Interference:Conducted and Radiated EMI emission and susceptibility, EMC Engineering Application. COUPLING MECHANISM: Coupling paths, Coupling via the supply network, Common mode coupling, Differential mode coupling, Impedance coupling, Radiative coupling, Ground loop coupling, Cable related emissions and coupling, Transient sources, Automotive transients. Categorization of the electromagnetic interference: emission, &hellip; EE 785 &#8211; Electromagnetic Interference and Compatibility Read More &raquo;","og_url":"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/","og_site_name":"EE IIT Bombay","article_modified_time":"2022-01-21T04:08:59+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/","url":"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/","name":"EE 785 - Electromagnetic Interference and Compatibility &ndash; EE IIT Bombay","isPartOf":{"@id":"https:\/\/www.ee.iitb.ac.in\/web\/#website"},"datePublished":"2022-01-21T04:08:58+00:00","dateModified":"2022-01-21T04:08:59+00:00","breadcrumb":{"@id":"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ee.iitb.ac.in\/webcourse_lists\/ee-785-electromagnetic-interference-and-compatibility\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ee.iitb.ac.in\/web\/"},{"@type":"ListItem","position":2,"name":"EE 785 &#8211; Electromagnetic Interference and Compatibility"}]},{"@type":"WebSite","@id":"https:\/\/www.ee.iitb.ac.in\/web\/#website","url":"https:\/\/www.ee.iitb.ac.in\/web\/","name":"EE IIT Bombay","description":"Department of Electrical Engineering, IIT Bombay","publisher":{"@id":"https:\/\/www.ee.iitb.ac.in\/web\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ee.iitb.ac.in\/web\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ee.iitb.ac.in\/web\/#organization","name":"Department of ELectrical Engineering | IIT Bombay","url":"https:\/\/www.ee.iitb.ac.in\/web\/","sameAs":[],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ee.iitb.ac.in\/web\/#\/schema\/logo\/image\/","url":"https:\/\/www.ee.iitb.ac.in\/webwp-content\/uploads\/2021\/11\/MicrosoftTeams-image-2.png","contentUrl":"https:\/\/www.ee.iitb.ac.in\/webwp-content\/uploads\/2021\/11\/MicrosoftTeams-image-2.png","width":93,"height":41,"caption":"Department of ELectrical Engineering | IIT Bombay"},"image":{"@id":"https:\/\/www.ee.iitb.ac.in\/web\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.ee.iitb.ac.in\/web\/wp-json\/wp\/v2\/course_lists\/4021"}],"collection":[{"href":"https:\/\/www.ee.iitb.ac.in\/web\/wp-json\/wp\/v2\/course_lists"}],"about":[{"href":"https:\/\/www.ee.iitb.ac.in\/web\/wp-json\/wp\/v2\/types\/course_lists"}],"wp:attachment":[{"href":"https:\/\/www.ee.iitb.ac.in\/web\/wp-json\/wp\/v2\/media?parent=4021"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}