TITLE: UHF CHARACTERISTICS OF PD AND CORONA IN A POINT-PLANE GAP UNDER DC POSITIVE, NEGATIVE, AND AC VOLTAGES
OBJECTIVE: To compare the UHF characteristics of partial discharge and corona under DC positive, DC negative, and AC voltage using point-plane electrode configuration..
CIRCUIT DIAGRAM: Click to see
EQUIPMENTS:
- HV test transformer
- Measuring capacitor
- Coupling capacitor
- DSM Peak Voltmeter
- DTM Partial discharge meter
- AKV Coupling quadripole
- PDG pulse generator
- Discharge rod
- HV flexible connector
- Series filter
- Electronic grounding switch
- Electrode
- Spectrum Analyzer (with FSH view software)
- Pre-amplifier
- UHF Antenna
ELECTRODE CONFIGURATION
- Point-plane gap
- Sphere gap
- Rod-sphere gap
PROCEDURE:
- Check earthing properly before starting the experiment.
- Run 1: Determine the correction factor of the circuit as mentioned before.
- Run 2: For UHF test on AC test setup, connect the circuit as described as Experiment
No. 1.
- Run 3: Place the UHF antenna as shown in schematic diagram and perform the experiment.
- Run 4: For UHF test on DC test setup, connect the circuit as described as Experiment No. 2 and follow the procedure as mentioned in Run 3.
- After capturing the UHF signal, connect the spectrum analyzer to the PC and using FSH view software extract the spectrums from it.
EXPERIMENTAL RESULTS:
List out all the spectrum captured by spectrum analyzer and make a comparison among them.